Introduction to CoDeSys Joining Long Strings

Working with strings in PLC programming sounds simple until it suddenly isn’t. Many developers hit problems when codesys joining long strings becomes part of logging, communication, or HMI work. Errors appear out of nowhere. Data gets cut. Sometimes the PLC even stops.

If you have faced these issues, you are not alone. String handling in CoDeSys requires planning, especially when dealing with large or dynamic text. This guide walks through practical, real-world ways to handle long strings safely, without crashes or surprises.

Understanding Strings in CoDeSys

What Is a STRING Data Type in CoDeSys

In CoDeSys, a STRING is an array of characters stored in memory. By default, it is not unlimited. It has a fixed maximum size defined at declaration time.

That detail is where most problems start.

Default STRING Length and Its Limitations

By default, a STRING holds 80 characters. Anything beyond that is either cut or causes unexpected behavior.

STRING vs STRING(n)
  • STRING → Default length (usually 80)
  • STRING(255) → Allows up to 255 characters
  • STRING(1024) → Suitable for long messages

When codesys joining long strings, using the default STRING is one of the most common mistakes.

Why Errors Occur When Joining Long Strings in CoDeSys

Memory Limits in PLC Systems

PLCs are not PCs. Memory is limited and tightly controlled. Long strings consume memory fast, especially when temporary variables are created during concatenation.

Buffer Overflow and Truncation Issues

If the destination string is shorter than the result, CoDeSys may:

  • Truncate silently
  • Throw runtime warnings
  • Cause unstable behavior

Runtime Errors vs Compile-Time Errors

Some errors appear only when the program runs with real data. This makes codesys joining long strings harder to debug if not planned properly.

Common Error Messages Seen During String Joining

String Too Long Errors

This appears when concatenation exceeds the declared string size.

Unexpected Truncation

No error message. Just missing characters. This is dangerous because it looks like the program works.

Application Crash or Watchdog Timeout

Heavy string operations inside loops can slow the PLC and trigger watchdog faults.

Basic Methods for CoDeSys Joining Long Strings

Using CONCAT Function

Result := CONCAT(Str1, Str2);

This works for small strings. It becomes risky for long ones.

Using the + Operator

Result := Str1 + Str2;

This creates temporary copies in memory, increasing risk.

Why These Methods Fail for Long Strings

Both methods assume the destination string is large enough. When codesys joining long strings, that assumption often breaks.

Using STRING(n) to Safely Join Long Strings

Defining Proper String Length

Always calculate the maximum possible length:

  • Static text
  • Variable data
  • Separators
  • Safety margin

Example:

VAR

    LogMessage : STRING(1024);

END_VAR

Best Practices for Length Calculation

If unsure, overestimate slightly. Memory is cheaper than crashes.

Step-by-Step Safe String Joining Approach

Initializing Strings Correctly

Always clear strings before reuse:

LogMessage := ”;

Appending in Small Chunks

Instead of joining everything at once, append step by step.

Chunk-Based String Joining Example

LogMessage := ”;

LogMessage := CONCAT(LogMessage, ‘Temp: ‘);

LogMessage := CONCAT(LogMessage, TempValue);

LogMessage := CONCAT(LogMessage, ‘ C’);

This approach reduces sudden memory spikes and helps codesys joining long strings safely.

Using CONCAT_EXT and Alternative Functions

When CONCAT_EXT Is Safer

Some CoDeSys versions offer extended string functions that manage memory better. These are safer for repeated appends.

Performance Considerations

Extended functions are slightly slower but far more stable for long operations.

Handling Strings in Loops Without Errors

FOR Loop String Appending

Appending inside loops is risky.

FOR i := 1 TO 100 DO

    LogMessage := CONCAT(LogMessage, DataArray[i]);

END_FOR

This can overflow quickly.

Avoiding Infinite Loops and Overflows

Always:

  • Check current string length
  • Break when approaching limits
  • Log partial data if needed

This is critical when codesys joining long strings dynamically.

Memory Optimization Tips for Long Strings

Reducing Temporary Variables

Avoid unnecessary intermediate strings. Reuse one main variable.

Clearing Strings After Use

After sending or logging:

LogMessage := ”;

This frees memory and improves stability.

Debugging CoDeSys Joining Long Strings

Monitoring String Length at Runtime

Use LEN() to monitor size:

CurrentLength := LEN(LogMessage);

This helps catch problems early.

Using Watch Windows and Logging

Watch string variables live. If length grows unexpectedly, stop and analyze.

Real-World Use Cases of Long String Joining

Logging and Data Export

System logs often require timestamps, values, and messages joined together.

Building JSON or CSV Strings

Communication with servers often needs structured text. This is a common case where codesys joining long strings becomes critical.

HMI and Communication Messages

Operator messages and alarms often exceed default string sizes.

Best Practices to Avoid Errors in the Future

Design-Level String Planning

Plan string sizes during design, not after errors appear.

Testing With Maximum Data Size

Always test with worst-case values, not average ones.

Final Thoughts on CoDeSys Joining Long Strings Without Errors

Handling strings in CoDeSys is not difficult, but it demands discipline. Most issues with codesys joining long strings come from underestimating size and memory behavior. With proper string declaration, safe appending methods, and runtime monitoring, long strings become stable and predictable.

Conclusion

Errors while joining long strings in CoDeSys are avoidable. The key is understanding limits, planning ahead, and writing defensive code. Treat strings like memory-sensitive data, not simple text. When done right, even complex logging and communication tasks run smoothly without crashes or data loss.

FAQs

1. Why does CoDeSys truncate long strings without warning?

Because the destination STRING length is smaller than the result.

2. What is the safest way to join long strings in CoDeSys?

Use STRING(n), append in steps, and monitor length at runtime.

3. Is CONCAT better than the + operator for long strings?

Both have limits, but step-by-step CONCAT is safer.

4. Can long string operations slow down a PLC?

Yes. Heavy string handling can trigger watchdog timeouts.

5. What string length should I use for logs or JSON data?

Usually STRING(512) or STRING(1024), depending on data size.

Comments